Multivariable transmitter 266CSH
The multivariable transmitters in the 266CSH calculates the mass flow for gases, vapours and liquids with dynamic flow compensation directly from the three process variables of differential pressure, absolute pressure and temperature.
- Base accuracy: ± 0.075 %
- Reduced process penetrations save money and reduce the risk of leakage
- High static working pressure option (41 MPa, 6000 psi) for power plants, pipelines or oil and gas production
- True draft range (down to 0.05 kPa, 0.2i nH2O) transmitter
- Local operation with LCD with TTG (Through The Glass) technology without the need of opening the housing
- Detection of plugged impulse lines
- Integrated totalizers and in addition a binary output as pulse or frequency output for activating external totalizers
- Exchangeable electronics with automatic configuration capability