HygienicMaster FEH500

Process Industry | The flowmeter is specifically designed for the food & beverage, pharmaceutical and biotechnology industries. Manufactured from FDA approved materials and certified in accordance with EHEDG and 3-A. Providing highest measuring accuracy & enhanced diagnosistics

Send Enquiry




    ?>

    The HygienicMaster FEH500 enhanced version is designed specifically for the food & beverage, pharmaceutical  and biotechnical industries. Manufactured from FDA approved materials and certified in accordance with 3-A.

    Available as integral mount design or remote mount design system.

    General specifications:

    • Measuring value error
      – Standard 0.4 % of rate, optional 0.2 % of rate
    • Nominal diameter
      – DN 1 to 100 (1/25 to 4 in.)
    • Process connection
      – Wafer type design
      – Flange in accordance with DIN 2501 / EN 1092-1, ASME B16.5 / B16.47, JIS
      – Threaded pipe connection in accordance with DIN 11851
      – Weld stubs
      – Tri-Clamp in accordance with DIN 32676, ASME BPE
      – External thread in accordance with ISO 228 / DIN 2999
    • Lining
      – PFA (vacuum tight)
    • Process connection material
      – Flange: stainless steel
      – Variable process connections: 1.4404
    • Communication
      – HART, PROFIBUS PA, FOUNDATION Fieldbus
    • Explosion protection approvals
      – ATEX, IECEx, FM, cFM, NEPSI, GOST
    • Certificates
      – 3-A, FDA-approved material

    Special features:

    • Batch functionality
      – Presetting counter, overrun correction, external start / stop, batch end contact