LST200

Send Enquiry




    ?>

    Ultrasonic level transmitter LST200

    Technical specifications

    Measurement
    • Measurement range
    0.35 to 8.00 m (13.78 to 314.96 in)
    Note:
    Operating conditions could attenuate the ultrasound, which may shorten the measurement range. Consult with ABB for applications involving bulk material, heavy vapor or dust, strong turbulence or foam.
    • Beam angle
    (@ -3 dB, full angle) : 10°
    • Accuracy and Repeatability
    ±3 mm or 0.25% of full span, whichever is larger
    Note:
    Accuracy and stability are further ensured by algorithm including temperature compensation, GAP regulator and noise filter.
    • Resolution
    1 mm
    • Update time
    2 s

    Electrical Data
    • Terminals
    Max. cable cross section:  1.5 mm2 (AWG 16)
    • Power supply
    LST200-Basic: 15 to 30 VDC.
    LST200-LCD: 19 to 30 VDC.
    Ripple: Maximum 5 %
    • Power consumption
    60mW to 600mW
    • Analog output
    Two-Wire output: 4 to 20 mA related to level/distance/volume/flow, full compensation for temperature effects
    • Integrated LCD display (Optional)
    Blue backlight, 6 mm height display with percentage bargraph
    Simplified two-button programming with easy set up menu enables fast configuration
    Real-time waveform
    Diagnostics message
    Totalized and actual flow indication
    Language: English and Chinese

    Mechanical Data
    • Housing and sensor enclosure: PC (Polycarbonate)
    Note: The chemical compatibility of the sensors must be checked
    before installation.
    • Dimensions
    90 × 81 × 209 mm (3.56 × 3.19 × 8.24 in)
    • Weight
    680 g
    • Cable entry
    M20 × 1.5 threaded bore for cable gland, directly on housing
    • Process xonnection
    M56x3.0, length 35mm

    Environmental Data
    • Electromagnetic compatibility (EMC)
    · IEC 61326-1 Table 2
    · CISPR Class B
    • Protect IP
    IP66/67 according to EN 60529
    IP68-rated up to 2 meters for 24 hours at room temperature
    • Temperature
    -30 to 60 °C (-22 to 140 ℉) , according to EN 60068-2-14
    -20 to 60 °C (-4 to 140 ℉) for display
    • Humidity
    Relative humidity: up to 100 %
    • Sensor Pressure
    Measurement functional from -4 to 44 psi
    (-0.25 to 3.0 bar)
    • Vibration resistance
    Random: according to EN 60068-2-64
    Shock: IEC 60068-2-27
    • Climate class
    IEC 60068-2-38 Test Z/AD

    Scroll to Top